![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-hCqK.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-oTK0.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-hCqK.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-lsWg.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-N0zS.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-evuT.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-pFrS.jpg#WildCard)
2-3 Days
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-hCqK.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-oTK0.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-hCqK.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-lsWg.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-N0zS.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-evuT.jpg#WildCard)
![4 Channel Voltage Current MODBUS Anolog Acquisition Module 4 Channel Voltage Current MODBUS Anolog Acquisition Module](https://fx.quarkscm.com.cn/product/xy/2000/2000/p/gu1/E/8/E13848/E13848-1-d7cb-pFrS.jpg#WildCard)
4 Channel Voltage Current MODBUS Anolog Acquisition Module
- SKU: 25142872
- Weight: 20.50g
- Dimensions (L x W x H): 5.50 x 4.00 x 2.50
- Dispatch Within : 15 Days
Features:
Operating voltage: dc 8-25v (dc 9v 12v 15v 24v)
Operating current: 10-14mA
MODBUS RTU Command support 03 06 function code.
V1(CH1) channel voltage measurement range is 0-5V, V2(CH2) channel voltage measurement range is 0-10V, C1/C2(CH3/4) channel current measurement range is 0-20MA/4-20MA.
Voltage resolution is 0.01V, measurement accuracy is 1%; current resolution is 0.1MA, measurement accuracy is 1%; if the error is greater than 1%, it can be calibrated.
MODBUS commands can be made serial HyperTerminal (serial assistant) OR PLC Enter.
Under the MODBUS command mode, it can support up to 247 devices in parallel.
Specifications:
Item size: 45 * 30 * 15mm / 1.77 * 1.18 * 0.59in
Item weight: 10g / 0.35ounces
Package size: 55 * 40 * 25mm / 2.16 * 1.57 * 0.98in
Packaeg weight: 12g / 0.42ounces
Note:
1.Due to the different display screen and light effect, the actual color of the item might be slightly different from the color showed on the pictures.
2.Please allow a little measuring deviation due to manual measurement.
Package List:
1 * Module
Operating voltage: dc 8-25v (dc 9v 12v 15v 24v)
Operating current: 10-14mA
MODBUS RTU Command support 03 06 function code.
V1(CH1) channel voltage measurement range is 0-5V, V2(CH2) channel voltage measurement range is 0-10V, C1/C2(CH3/4) channel current measurement range is 0-20MA/4-20MA.
Voltage resolution is 0.01V, measurement accuracy is 1%; current resolution is 0.1MA, measurement accuracy is 1%; if the error is greater than 1%, it can be calibrated.
MODBUS commands can be made serial HyperTerminal (serial assistant) OR PLC Enter.
Under the MODBUS command mode, it can support up to 247 devices in parallel.
Specifications:
Item size: 45 * 30 * 15mm / 1.77 * 1.18 * 0.59in
Item weight: 10g / 0.35ounces
Package size: 55 * 40 * 25mm / 2.16 * 1.57 * 0.98in
Packaeg weight: 12g / 0.42ounces
Note:
1.Due to the different display screen and light effect, the actual color of the item might be slightly different from the color showed on the pictures.
2.Please allow a little measuring deviation due to manual measurement.
Package List:
1 * Module
Recommend For You
Features:
Well thermal stability: according to the using conditions of graphite crucible snap heat and cold.
Well corrosion resistance, impact resista..
Features:
Well thermal stability: according to the using conditions of graphite crucible snap heat and cold.
Well corrosion resistance, impact resista..
Features:
Well thermal stability: according to the using conditions of graphite crucible snap heat and cold.
Well corrosion resistance, impact resista..
Features:
Well thermal stability: according to the using conditions of graphite crucible snap heat and cold.
Well corrosion resistance, impact resista..
Features:
Detects all combustible gas.
Long flexible stainless probe reaches all areas.
Adjustable sensitivity.
Fast warm-up.
Super sensitive, respo..